7. Configure controller 2 IP address using in‐band management port:
8. Enable OpenFlow instance 1:
9. Create OpenFlow switch instance 2 and add data ports:
10. Configure controller 1 IP address using in‐band management port:
11. Configure controller 2 IP address using in‐band management port:
12. Enable OpenFlow instance 2:
© Copyright Lenovo 2016
RS G8264(configopenflowinstance)# controller 2 address 172.21.100.73
dataport
(Switch connects with controller 2 via the in‐band management port; default controller port is used in this
example)
RS G8264(configopenflowinstance)# enable
RS G8264(configopenflowinstance)# exit
RS G8264(config)# openflow instance 2
RS G8264(configopenflowinstance)# member 26,27,2832
RS G8264(configopenflowinstance)# controller 1 address 172.21.100.73
dataport
(Switch connects with controller 1 via the in‐band management port; default controller port is used in this
example)
RS G8264(configopenflowinstance)# controller 2 address 172.22.100.73
dataport
Switch connects with controller 2 via in‐band management port; default controller port is used in this
example)
RS G8264(configopenflowinstance)# enable
RS G8264(configopenflowinstance)# exit
View OpenFlow Configuration:
RS G8264(config)# show runningconfig
(Create OpenFlow instance 2)
(Add data ports 26,27, and data port
range 28 through 32 as members of
OpenFlow instance 2)
Chapter 15: OpenFlow