Drive Configuration (Fdd, Slm, Msd) - Siemens SINUMERIK FM-NC Installation And Startup Manual

Hide thumbs Also See for SINUMERIK FM-NC:
Table of Contents

Advertisement

03.96
6.9.2

Drive configuration (FDD, SLM, MSD)

Note
The drive configuration and start-up of synchronous linear motors (SLM) are
described in
References:
There are no drive parameters stored in the control in the delivery state or after
a general reset.
Before the drives can be parameterized, the drive configuration (power sections
and motors) connected to the control system must be entered and assigned to
the axes declared in MD 20070: AXCONF_MACHAX_USED/ MD 10000: AX-
CONF_MACHAX_NAME_TAB.
Fig. 6-5
Note
The settings made in the display "Drive configuration" are described one by
one below.
Setting the drive
The drive configuration settings are entered in the "Drive configuration" display
configuration
on the MMC or 611D start-up tool. You can call up this display via the Machine
data / Drive configur.
S
S
S
 Siemens AG 2000 All Rights Reserved
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
6 Assigning Parameters to the Control and the PLC Program
/FBLI/ Description of Functions, Linear Motor.
Drive configuration display with MMC102/103 (SW 4.1 and higher)
A physical slot number is assigned to each power section.
If a slot is not used or no power section installed, then it must be coded as
passive.
A logical address via which the relevant drive is addressed (setpoint/actual
value assignment, access to parameters) is assigned to each slot used.
6.9
Axes and spindles
6-111
6

Advertisement

Table of Contents
loading

Table of Contents