Protection level concept
Protection levels
Protection
levels 0–3
6-90
Protection levels for enabling data areas are implemented in the
SINUMERIK 840D. There are protection levels 0 to 7;
0 is the highest and
7 is the lowest. Protection levels
S
0 to 3 are disabled by means of a password and
S
4 to 7 by means of keyswitch positions.
The operator only has access to information protected by one particular level
and the levels below it. The machine data are assigned various protection lev-
els as standard.
Protection level 4 (keyswitch position 3) and higher is required to display ma-
chine data.
The appropriate protection level must generally be enabled by means of pass-
word "EVENING" to start up the system.
Note
For information about changing protection levels, refer to
References:
/BA/ Operator's Guide
/FB/ A2, Various Interface Signals
Table 6-2
Protection level concept
Protection level
0
Password
1
Password: SUNRISE (default)
2
Password: EVENING (default)
3
Password: CUSTOMER (default)
4
Keyswitch position 3
5
Keyswitch position 2
6
Keyswitch position 1
7
Keyswitch position 0
Protection levels 0 to 3 require the input of a password. The password for
level 0 provides access to all data areas. The passwords can be changed after
activation (not recommended). If, for example, the passwords have been forgot-
ten, then the system must be reinitialized (NCK general reset). This sets all
passwords back to the standard settings of this software version.
The password remains valid until it is reset with the DELETE PASSWORD soft-
key. A POWER ON does not reset the password.
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
Locked by
Installation engineer, service
Programmer, machine setter
 Siemens AG 2000 All Rights Reserved
03.96
Area
Siemens
Machine manufacturer
End user
Qualified operator
Trained operator
Semi-skilled operator

Advertisement

Table of Contents
loading

Table of Contents