Memory Configuration - Siemens SINUMERIK FM-NC Installation And Startup Manual

Hide thumbs Also See for SINUMERIK FM-NC:
Table of Contents

Advertisement

6 Assigning Parameters to the Control and the PLC Program
6.7

Memory configuration

6.7
Memory configuration
Hardware
configuration
Memory areas
Activation
6-102
The following table shows the hardware configuration of the available NC
CPUs:
D-RAM
NCU 570
NCU 571
4 MB
NCU 572
8 MB
NCU 573
8 MB
NCU 573.2
8 MB
NCU 573.2
32 MB*
*) available as an option, see Catalog NC 60.1
The memory areas for user data in the NC are preset to suit most user require-
ments during an NCK general reset. The following areas can be adjusted to
achieve optimum utilization of the available user memory:
S
Tool management
S
Tool offsets
S
User variables
S
R parameters
S
Compensations (e.g. LEC)
S
Protection zones
S
Frames
The memory must be sectionalized before commencement of the actual start-up
process because all buffered user data (e.g. part programs, drive data) are lost
when the memory is re-allocated. Machine data, setting data and options are
not erased.
The MDs for the memory configuration are activated by power ON.
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
S-RAM
S-RAM
not
buffered
buffered
1.5 MB
0.25 MB
0.5 MB/2.0 MB*
0.5 MB/2.0 MB*
0.5 MB/2.0 MB*
2.0 MB
2.0 MB
 Siemens AG 2000 All Rights Reserved
03.96
FLASH
PCMCIA
2.25 MB
4 MB
4 MB
4 MB
4 MB
4 MB