6 Assigning Parameters to the Control and the PLC Program
6.4

Machine data masking filter (SW 4.2 and higher)

6.4
Machine data masking filter (SW 4.2 and higher)
6.4.1

Function

6.4.2
Selecting and setting the machine data masking filters
Selecting the
list displays
6-92
If you use the masking filter, you can reduce the number of machine data dis-
played and adapt it to the user's requirements.
All machine data in the areas
S
General machine data
S
Channel-specific machine data
S
Axis-specific machine data
S
Drive machine data (FDD/MSD)
are assigned to certain groups.
You can see to which group a machine data belongs in the
machine data list.
Reference
/LIS/ Lists
S
Each area has its own division into groups
S
Each machine data in the areas can be assigned to several groups.
The filters are selected and activated in a list display that is opened with the
Display options vertical softkey in the relevant machine data areas.
Fig. 6-2
Display options screen for setting the masking filter