Static Ram Memory - Siemens SINUMERIK FM-NC Installation And Startup Manual

Hide thumbs Also See for SINUMERIK FM-NC:
Table of Contents

Advertisement

6 Assigning Parameters to the Control and the PLC Program
6.7
Memory configuration
6.7.2

Static RAM memory

Table 6-7
MDs for allocating SRAM
MDs for SRAM
MD 18120: MM_NUM_GUD_NAMES_NCK
MD 18130: MM_NUM_GUD_NAMES_CHAN
MD 18080: MM_TOOL_MANAGEMENT_MASK
MD 18082: MM_NUM_TOOL
MD 18100: MM_NUM_CUTTING_EDGES_IN_TOA
MD 18160: MM_NUM_USER_MACROS
MD 18190: MM_NUM_PROTECT_AREA
MD 28200: MM_NUM_PROTECT_AREA_CHAN
MD 28210: MM_NUM_PROTECT_AREA_ACTIV
MD 28050: MM_NUM_R–PARAM
MD 28080: MM_NUM_USER_FRAMES
MD 38000: MM_ENC_COMP_MAX_POINTS
SRAM with
2 MB module
SRAM check
6-104
Set the following machine data:
If the NCU 571/572/573 with larger memory is used, the memory must be
enabled.
S
Enter value 1900 in MD 18230: MM_USER_MEM_BUFFERED.
S
Make a copy of the series installation file.
S
Perform POWER ON (the memory is reorganized).
S
Reload series installation file in the control.
MD 18060 shows how much user memory is still available.
Recommendation:
Values greater than 15000 should be displayed so that data (e.g. tool offsets)
can be imported at any time.
Note
Under normal circumstances do not change any of the other memory settings!
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
Meaning
Number of global user data
Number of channel-specific global user variables
Memory allocation for tool management
Set the tool management parameters according to
the machine requirements. If you are not using the
TM function, set MD 18084 and 18086 to "0". This
gives you more part program memory.
Number of tools according to machine
Number of tool cuttings edges per TOA module ac-
cording to requirements of end customer
Number of macros
Number of files for machine-related protection
zones
Number of files for channel-specific protection
zones
Number of protection zones simultaneously active in
one channel
Number of R parameters required
Number of frames required
Number of compensation points required
 Siemens AG 2000 All Rights Reserved
03.96

Advertisement

Table of Contents
loading

Table of Contents