Upgrading The Mmc 100/100.2/101 Software - Siemens SINUMERIK FM-NC Installation And Startup Manual

Hide thumbs Also See for SINUMERIK FM-NC:
Table of Contents

Advertisement

12 Software and Hardware Replacement

12.2 Upgrading the MMC 100/100.2/101 software

12.2
Upgrading the MMC 100/100.2/101 software
Medium supplied
Floppy disk set 1
Floppy disk set 2
12-286
The MMC100/101 software is supplied on 2 (3.5") floppy disks. They consist of:
1. System disk(s) (also called installation disk).
– Boot software
– System software
– User software
2. Application disk(s)
– Alarm text files
– Configuration files for MMC 100/100.2/101 MDs
– Configuration file for several operator panels
– User software
When you have loaded floppy disk set 1, you have a functionally standard
MMC 100/100.2/101 system with the first language English and the second lan-
guage German. The alarm text and message files contain only Siemens texts.
The contents of floppy disk set 2 enable you to do the following:
– Adapt and expand alarm text files
– Select one or two languages other than those already loaded from floppy
disk set 1 (a maximum of 2 languages are loaded on the MMC100 at any
given time).
– Make special MMC 100/100.2/101 MD settings
– Adapt configuration parameters for several operator panels/NCUs.
– Transfer user-defined screen forms for PLC status to
MMC100/100.2/101
Instructions on how to handle the two diskettes are given below. You will find
rules for adapting files before transfer to MMC 100 in Chapter 11 Data Backup.
For further information see
/IAM/ IM1, Start-Up Functions for MMC 100.2
SINUMERIK 840D Installation and Start-Up Guide (IAD) – 04.00 Edition
 Siemens AG 2000 All Rights Reserved
04.00
03.96