EAS28040
CHECKING THE RELAYS
Check each switch for continuity with the digital
circuit tester. If the continuity reading is incor-
rect, replace the relay.
Digital circuit tester
90890-03174
Model 88 Multimeter with tachom-
eter
YU-A1927
1. Disconnect the relay from the wire harness.
2. Connect the digital circuit tester and battery
(12 V) to the relay terminal as shown.
Check the relay operation.
Out of specification → Replace.
Starter relay
3
4
1. Positive battery terminal
2. Negative battery terminal
3. Positive tester probe
4. Negative tester probe
Result
Continuity
(between "3" and "4")
Relay unit (starting circuit cut-off relay)
3
R
L/W
L/W L/Y R/W L/B B/R Sb B/Y Lg
1. Positive battery terminal
2. Negative battery terminal
3. Positive tester probe
4. Negative tester probe
1
2
2
4
1
R/B
W/L
R/L
ELECTRICAL COMPONENTS
Result
Continuity
(between "3" and "4")
Relay unit (fuel injection system relay)
3
R
L/W
1. Positive battery terminal
2. Negative battery terminal
3. Positive tester probe
4. Negative tester probe
Result
Continuity
(between "3" and "4")
Headlight relay
3
4
2
Y/
B
L/
R/Y
1. Positive battery terminal
2. Negative battery terminal
3. Positive tester probe
4. Negative tester probe
Result
Continuity
(between "3" and "4")
8-157
2
1
R/B
W/L
R/L
L/W L/Y R/W L/B B/R Sb B/Y Lg
+
1
R/Y
B
4