3.14.2 Master/Slave Linking Programming; Figure 3-17: Mx8000 Master/Slave Receiver Linking Cabling Connections - Honeywell ADEMCO MX8000 Installation And Operation Manual

Digital alarm receiver
Hide thumbs Also See for ADEMCO MX8000:
Table of Contents

Advertisement

that is not required. The cabling used is standard 4-wire RJ-11 cables (see Figure 3–18) for the
interconnection of the receivers, a standard 25 pin printer cable as described in Section 3.10 and 3.10.1, and
a DTE cable for the automation computer connection as described in Section 3.13. See Section 3.14.2 for
Master/Slave Linking Programming Procedures.
Notes:
For FM installations, the printer or any automation system connection must be within 20 ft. (6m) of the
MX8000 and in the same room as the MX8000. The Okidata Microline 320 is the only FM approved printer
for use with the MX8000.
If necessary (in non-FM installations), a serial printer can be used as the automation backup printer. In
that situation, connect the serial cable from the COM2 port of the Master Receiver to the printer and omit
the parallel printer connection.

3.14.2 Master/Slave Linking Programming

The receivers may be programmed for master/slave linking to report to an automation computer and/or
printer. The receivers must be programmed for master/slave linking on power-up when this feature is used.
To perform linking programming, see 3.14.2.1 Master Printer/Slave Printer Linking Programming or
3.14.2.2 Master Automation/Slave Automation Linking Programming below.
Note: If it is desired to use linking for both the automation computer and printer, perform the procedures in
3.14.2.2 Master Automation/Slave Automation Linking Programming below. Printer linking will
automatically be in effect when these procedures are performed.
SLAVE
120 VAC ± 10%
240 VAC ± 10%
50-60 Hz
100 VA
WARNING!
HIGH VOLTAGE PRESENT
DISCONNECT AC LINE AND
ALL OTHER CONNECTORS
PROIR TO SERVICING
RELAY RATING
2.5A 48VAC/VDC
COM 1
COM 2
SBUS
AUTOMATION
COMPUTER PORT 3
SLAVE
120 VAC ± 10%
240 VAC ± 10%
50-60 Hz
100 VA
WARNING!
HIGH VOLTAGE PRESENT
DISCONNECT AC LINE AND
ALL OTHER CONNECTORS
PROIR TO SERVICING
RELAY RATING
2.5A 48VAC/VDC
COM 1
COM 2
SBUS
NOTE
LIMIT TO ONE MASTER AND TWO SLAVES.
Figure 3–17: MX8000 Master/Slave Receiver Linking Cabling Connections
SLAVE
120 VAC ± 10%
240 VAC ± 10%
50-60 Hz
FUSE
100 VA
2.5A
SLOW BLOW
WARNING!
REPLACE ONLY
WITH A FUSE
HIGH VOLTAGE PRESENT
DISCONNECT AC LINE AND
OF SAME TYPE
ALL OTHER CONNECTORS
PROIR TO SERVICING
RELAY RATING
2.5A 48VAC/VDC
BATT-
UNUSED
COM 1
BATT+
RLY NO
RLY NC
RLY COM
PARALLEL
COM 2
SBUS
AUTOMATION
COMPUTER PORT 2
Master Printer/Slave Printer Linking
SLAVE
120 VAC ± 10%
240 VAC ± 10%
50-60 Hz
FUSE
100 VA
2.5A
SLOW BLOW
WARNING!
REPLACE ONLY
HIGH VOLTAGE PRESENT
WITH A FUSE
OF SAME TYPE
DISCONNECT AC LINE AND
ALL OTHER CONNECTORS
PROIR TO SERVICING
RELAY RATING
2.5A 48VAC/VDC
COM 1
BATT-
UNUSED
BATT+
RLY NO
RLY NC
RLY COM
PARALLEL
COM 2
SBUS
Master Automation/Slave Automation Linking
MASTER
120 VAC ± 10%
240 VAC ± 10%
50-60 Hz
FUSE
100 VA
2.5A
SLOW BLOW
WARNING!
REPLACE ONLY
WITH A FUSE
HIGH VOLTAGE PRESENT
DISCONNECT AC LINE AND
OF SAME TYPE
ALL OTHER CONNECTORS
PROIR TO SERVICING
RELAY RATING
2.5A 48VAC/VDC
BATT-
UNUSED
COM 1
BATT+
RLY NO
RLY NC
RLY COM
PARALLEL
COM 2
SBUS
RJ-11
(TYP.)
AUTOMATION
COMPUTER PORT 1
MASTER
120 VAC ± 10%
240 VAC ± 10%
50-60 Hz
FUSE
100 VA
2.5A
SLOW BLOW
WARNING!
REPLACE ONLY
HIGH VOLTAGE PRESENT
WITH A FUSE
OF SAME TYPE
DISCONNECT AC LINE AND
ALL OTHER CONNECTORS
PROIR TO SERVICING
RELAY RATING
2.5A 48VAC/VDC
COM 1
BATT-
UNUSED
BATT+
RLY NO
RLY NC
RLY COM
PARALLEL
COM 2
SBUS
RJ-11
(TYP.)
Section 3 – Installation
PRINTER
FUSE
2.5A
SLOW BLOW
REPLACE ONLY
WITH A FUSE
OF SAME TYPE
BATT-
UNUSED
BATT+
RLY NO
RLY NC
RLY COM
PARALLEL
PRINTER
FUSE
2.5A
SLOW BLOW
REPLACE ONLY
WITH A FUSE
OF SAME TYPE
BATT-
UNUSED
BATT+
RLY NO
RLY NC
RLY COM
AUTOMATION
PARALLEL
COMPUTER
3–13