Table 5-12: Mx8000-Lc3 Edit Line List Items And Description; Figure 5-13: Mx8000-Lc3 Handshake Sequence Menu; Figure 5-14: Mx8000-Lc3 Handshake Order Number - Honeywell ADEMCO MX8000 Installation And Operation Manual

Digital alarm receiver
Hide thumbs Also See for ADEMCO MX8000:
Table of Contents

Advertisement

2
4. Press
to choose Line Device menu.
1
5. Press
to select MX8000–LC3 (3 Line)
2
6. Press
to edit line.
The display will show a list of the existing Lines.
7. Press the
or
8. When the equal sign is on the Line you wish to edit:
ENTER
Press
.
MENU
The display will show a list of choices. Table 5–12 lists these choices and a brief description.
Edit Line List
1 Handshake Seq
2 Pulse Format
3 Line Options
4 Listen In
5 Misc. Line Opt.
6 Ademco Auto Opt.
7 Line Gain Opt.
5.5.2.1
Handshake Sequence
Each line card is intelligent enough to determine
what format is being sent from a reporting panel. You
only need to program the handshake order and
parameters for each Line. A Line will initiate up to six
different types of handshake tone groups. The order in
which the receiver sends out these handshake signals
can be changed in this program location for each line
card. Table 6–1 in Section 6 lists the proper
handshake to use for the type of communication
format you are using with a panel.
Follow these steps to change the handshake order and
or the parameters associated with the handshake.
To Change the Handshake Sequence Number:
Handshake sequence sets the order in which the receiver will send out handshakes.
1. Follow the procedures in Section 5.5.2.
1
2. Press
for handshake sequence menu.
When display flashes on the Hs# (see Figure 5–13).
3. Press the
or
handshake number.
1 = the first handshake tone sent
handshake tone to be sent and so on.
4. When the desired order number is flashing press
The display will start flashing the format group field.
arrow buttons to move through the available list.
Table 5–12: MX8000–LC3 Edit Line List Items and Description
This function is used to program the handshake order and parameters for this Line.
Used to set the 5- and 6-digit format, Interdigit timeout, acknowledgement, and to select if
partially extended is enabled.
Used to set number of rings, ring on/off duration, threshold voltage, and sample time.
Used to program the parameters for the listen in (two-way voice communication) feature if
used. Must not be used in UL installations.
Used to program hunt group number, enable or disable echo suppression, and billing delay.
Used to select the BFSK auto output, 3/1 restore output, pulse output, and FBII output.
Used to select the transmit and receive line gain and some Caller ID gain options.
button to change the ordered
2 = the second
Description
<Edit Line: 01>
1=Handshake Seq.
2 Pulse Format
3 Line Options
Hs=1
Gr=1400-2300–2
Wait=1250 AckDur=0800
<Seq # <=Exit>
Figure 5–13: MX8000–LC3 Handshake Sequence
Hs=1
Wait=1250 AckDur=0800
<Seq # <=Exit>
Figure 5–14: MX8000–LC3 Handshake Order
ENTER
or
.
MENU
Section 5 – Programming
¯
Dur=0100
Menu
Gr=1400_2225–2
Dur=0100
Number
5–39

Advertisement

Table of Contents
loading

Table of Contents