Iosmodportman-3 - Cisco Catalyst 4500 Series System Message Manual

Cisco ios system message guide ios release 12.2(37)sg
Hide thumbs Also See for Catalyst 4500 Series:
Table of Contents

Advertisement

Chapter 2
Messages and Recovery Procedures
IOSMODPORTMAN-4
Error Message C4K_IOSMODPORTMAN-4-CRITICALTEMP: Chassis temperature is at or over
critical threshold - current temp: [dec]C, critical threshold: [dec]C
Error Message C4K_IOSMODPORTMAN-4-CLOCKMODULEFAULTY: Clock module switched to [dec]
reason [char] for more info use the cmd:'show environment status clock'
Error Message C4K_IOSMODPORTMAN-4-INLINEPOWEROVERMAX:Inline power exceeds max
threshold:Module status changed to 'Pwr Max'
Error Message C4K_IOSMODPORTMAN-4-MODULECRITICALTEMP: Module [dec] Sensor [char]
temperature i s at or over critical threshold - current temp: [dec]C, critical
threshold: [dec]C
OL-13091-01
The chassis temperature is above a critical threshold. If some action is not taken
Explanation
immediately to cool the chassis, the system shuts down to prevent damage to the hardware.
Remove one or more modules to reduce the temperature of the chassis, and
Recommended Action
check if the fan tray is functional.
The clock module is faulty and may have to be replaced.
Explanation
Contact your technical support representative to confirm that replacing the
Recommended Action
clock module is necessary.
The measured PoE usage is higher than the module's physical limit. This situation can
Explanation
be caused by misconfiguration or by one or more unauthorized appliances drawing more PoE than
allocated. In installations with a 1400 W DC power supply, this warning can be a false positive.
Refer to bug id CSCef49715.
Recommended Action
Make sure that the right amount of PoE is allocated to each device. If the PoE
allocation is correct, remove powered devices one at a time and see if the power usage decreases as
expected. (You can use the show power detail command to see the PoE allocated to the module and
the PoE used.) If the power usage decreases sharply when a device is disconnected, chances are that
this device is using more PoE than allocated. Avoiding using this device should solve your problem.
If after disconnecting all the devices on the module, the PoE usage is still high, and the system does
not use 1400 W DC power, contact you technical support representative.
A module temperature is above its critical threshold. If some action is not taken
Explanation
immediately to cool down the module then the module will be shut down to prevent damage to
hardware.
Try removing and reinserting the module. If the problem persists, replace the
Recommended Action
module.
Catalyst 4500 Series Switch Cisco IOS System Message Guide
IOSMODPORTMAN Messages