Chapter 2
Messages and Recovery Procedures
Error Message C4K_HW-3-X2OUIREGREADFAILURE:Error while reading Supervisor X2 OUI
register Device Addr: [dec]
Error Message C4K_HW-3-X2LOOPBACKFAILURE: Failed to put [char] Xaui([dec]) [char]
loopback

HWACLMAN Messages

This section contains the hardware ACL Manager (HWACLMAN) messages.
Error Message C4K_HWACLMAN-4-ACLHWPROGERR: [input/output]
limit,
Error Message C4K_HWACLMAN-4-ACLHWPROGERRREASON:[input/output]
[char] -
Error Message C4K_HWACLMAN-4-CAMAUDIT: ACL/QOS CAM Health Check: [input/output]
[char] Index:
OL-13091-01
There was an unexpected error when accessing a hardware device with the given device
Explanation
address.
Contact your technical support representative. You will probably need to
Recommended Action
replace the supervisor engine.
Software was unable to put the X2 in or out of loopback because it was unable to
Explanation
determine the X2 type.
This is an informational message only. No action is required.
Recommended Action
[char]
Some ACL-based features cannot be fully programmed into the hardware. Packets that
Explanation
use these features complete processing in the software. If the feature is a policy map, then QoS is
completely disabled (on the specific interface).
This message lists the impacted feature; further messages list the specific failure that occurred.
Recommended Action
This is an informational message only. No action is required.
[char]
This message provides a specific failure that prevented ACL-based features from being
Explanation
fully programmed into the hardware.
This is an informational message only. No action is required.
Recommended Action
[dec] [char] (Cumulative Error Count:
The background system health monitor detected a potential problem.
Explanation
If this is a software error, the system has already corrected itself automatically
Recommended Action
and no action is required. If this is a hardware error, power cycle the switch.