Chapter 2
Messages and Recovery Procedures
Error Message C4K_REDUNDANCY-3-COMMUNICATION: Communication with the peer Supervisor
has been [char]
Error Message C4K_REDUNDANCY-3-NOT_READY_FOR_SWITCHOVER: The active Supervisor
failed but standby supervisor cannot initiate
standby Supervisor.
Error Message C4K_REDUNDANCY-3-PEER_RELOAD: The peer Supervisor is being reset
because [char]
Error Message C4K_REDUNDANCY-3-SIMPLEX_MODE: The peer Supervisor has been lost
REDUNDANCY-4
Error Message C4K_REDUNDANCY-4-CONFIGSYNCFAIL:Persistent-config Sync to Standby
supervisor failed.
Error Message C4K_REDUNDANCY-4-KEEPALIVE_WARNING: Keepalive messages from peer
Supervisor are
OL-13091-01
The status of the peer supervisor engine communication path changed.
Explanation
Recommended Action
This is an informational message only. No action is required.
The standby supervisor engine is currently in an intermediate state and cannot take over
Explanation
for the primary supervisor engine.
This is an informational message only. No action is required.
Recommended Action
Explanation
The supervisor engine was reset for the reason specified by [char]. See the reported error
message for the specific reason. This allows recovery from an indeterminate standby state.
Recommended Action
This is an informational message only. No action is required.
Explanation
The peer supervisor engine is absent, and the switch shifted to nonredundant mode.
This is an informational message only. No action is required.
Recommended Action
The active supervisor engine failed to receive a confirmation message from the standby
Explanation
supervisor engine. There is a potential problem with the standby supervisor engine.
Contact your technical support representative.
Recommended Action
missing for [dec] seconds
Keepalive messages have not been sent from the peer supervisor engine. If the situation
Explanation
persists and the keepalive messages do not resume, the peer supervisor engine will eventually be
reset. This message is logged for every third missed keepalive message.
This is an informational message only. No action is required.
Recommended Action
Switchover activity. Resetting