Cisco Catalyst 4500 Series System Message Manual page 29

Cisco ios system message guide ios release 12.2(37)sg
Hide thumbs Also See for Catalyst 4500 Series:
Table of Contents

Advertisement

Chapter 2
Messages and Recovery Procedures
Error Message C4K_CHASSIS-3-TRANSCEIVERSERIALINTEGRITYCHECKFAILED: transceivers on
ports [char] and [char] have duplicate serial numbers
Explanation
port in the faulty status.
All transceivers must have a unique serial number. If this message appears you likely have a cloned
transceiver SEEPROM.
Recommended Action
Error Message C4K_CHASSIS-3-STUBPHYMISMATCH: Stub type mismatch: stub [dec]/[dec] is
type [dec], should be type [dec]
Explanation
Recommended Action
Error Message C4K_CHASSIS-3-SUPERVISORTYPEMISMATCHINSPROM: Supervisor's FPGA
register type is [dec], but supervisor's serial eeprom type is [dec]
Explanation
supervisor engine's serial EEPROM. This might happen if the IDPROM is misprogrammed or the
supervisor engine's FPGA register somehow returns an incorrect value. Both are extremely unlikely.
Recommended Action
using the show idprom supervisor command. The output should be the same as the number printed
in this log message for the FPGA register type. This should never happen with a production
supervisor engine. If it does, replace the supervisor engine.
Error Message C4K_CHASSIS-3-TEMPERATURESENSORREADFAILED: Failed to read the
supervisor temperature sensor
Explanation
overheated, this condition will not be reported.
Recommended Action
is required. If this message appears repeatedly (once every 30 minutes), inspect and, if necessary,
replace the temperature sensor on the supervisor engine.
Error Message C4K_CHASSIS-3-UNKNOWNLINECARD: Unknown module (Field Replaceable Unit
minor type [dec]) in slot [dec]
Explanation
recognize this module. A software upgrade is necessary.
Recommended Action
OL-13091-01
Only Cisco-qualified transceivers are supported. Other transceivers place the associated
Replace the transceiver with a transceiver that Cisco supports.
The stubs have non-matching physical types for the specified module.
Verify that the physical types for every stub on the module match.
The type in the supervisor engine's FPGA register doesn't match the type in the
Check the FruMinorType field in the supervisor engine's serial EEPROM,
The temperature sensor on the supervisor engine cannot be read. If the chassis becomes
If this message appears only once, this error could be transient and no action
The module's serial EEPROM was readable, and your software image does not
Upgrade the software to a version that is compatible with the module.
Catalyst 4500 Series Switch Cisco IOS System Message Guide