Cisco Catalyst 4500 Series System Message Manual page 30

Cisco ios system message guide ios release 12.2(37)sg
Hide thumbs Also See for Catalyst 4500 Series:
Table of Contents

Advertisement

CHASSIS Messages
CHASSIS-4
Error Message C4K_CHASSIS-4-CANTWRITESUPERVISORSPROM:Writing the supervisor's SPROM
is not supported
Error Message C4K_CHASSIS-4-INLINEPOWERRESTORED:Resuming normal phone operation
since inline power has been restored
Error Message C4K_CHASSIS-4-OVERHEATINGOVER: Resuming normal operation after return
to acceptable temperatures.
Error Message C4K_CHASSIS-4-SUFFICIENTFANSRESTORED: Resuming normal operation after
restoration of adequate fan cooling
Error Message C4K_CHASSIS-4-SLOTOVERHEATINGOVER: Resuming normal operation in slot
[dec] after return to acceptable temperatures.
Error Message C4K_CHASSIS-4-SUFFICIENTMODULEPOWERRESTORED: Module in slot [dec]
resuming normal operation after restoration of adequate power
Catalyst 4500 Series Switch Cisco IOS System Message Guide
2-12
Rewriting the supervisor engine's serial programmable read-only memory (SPROM) is
Explanation
not allowed, because if it is done incorrectly, it could make the system unusable.
This is an informational message only. No action is required.
Recommended Action
PoE to the switch was restored, and normal phone operation will resume.
Explanation
This is an informational message only. No action is required.
Recommended Action
The unit's modules were reset to reduce heat generation, because the unit reached a
Explanation
critical temperature. The switch is now cool enough to return to normal operation.
This is an informational message only. No action is required.
Recommended Action
The modules were reset to reduce heat generation because there were not enough
Explanation
working fans. Adequate fan cooling is now restored, and the switch will resume normal operation.
Recommended Action
This is an informational message only. No action is required.
Explanation
The module has been reset to reduce heat generation since it exceeded critical
temperature. It has returned to acceptable temperature and normal operation is resuming.
This is an informational message only. No action is required.
Recommended Action
The module was reset to conserve power because the system had inadequate power
Explanation
available. The switch now has adequate power and is resuming normal operation.
This is an informational message only. No action is required.
Recommended Action
Chapter 2
Messages and Recovery Procedures
OL-13091-01