SWITCHINGENGINEMAN Messages
Error Message C4K_SWITCHINGENGINEMAN-3-PACKETMEMORYERROR2: Multiple Errors in
Packet Memory [dec]
Explanation
indicate a hardware problem.
Recommended Action
contact your technical support representative, and provide the representative with the gathered
information.
Error Message C4K_SWITCHINGENGINEMAN-3-PACKETMEMORYPARITYERROR: Parity error in
Packet Memory at address
Explanation
hardware problem or a more permanent problem. After 128 packet memory and queue memory
errors, the switch reloads automatically.
Recommended Action
the switch boots, run the show diagnostics online command and send the results to your technical
support representative.
Error Message C4K_SWITCHINGENGINEMAN-3-PACKETMEMORYTESTFAILURE:Packet Memory buffer
test failed!!!
Explanation
operation to continue.
Recommended Action
Error Message C4K_SWITCHINGENGINEMAN-3-PACKETMEMORYTESTPARTIALFAILURE:Packet Memory
buffer test detected errors with [dec] % of the packet buffers. Switch operation
will continue, with potentially reduced performance. Use 'show diagnostic result
module all detail' command to see test results.
Explanation
sufficient number of working buffers to enable switch operation.
Recommended Action
results. Refer to the Release Note attachment in the DDTS for CSCdz57255.
Error Message C4K_SWITCHINGENGINEMAN-3-PPECELLDUPDETECTED: Free cell duplicate(s)
detected [hex]. System will be reset!
Explanation
erroneously appear when using jumbo packets or if sharing is configured and transmit queues have
backed up.
Recommended Action
Catalyst 4500 Series Switch Cisco IOS System Message Guide
2-118
Multiple errors in packet memory were detected. If this message persists, it might
If this message persists, use the show platform commands to show results,
[dec] , total errors= [dec]
There is a parity error in packet memory. This condition might indicate a transient
If this message reoccurs, reboot the switch. If the message appears every time
Insufficient packet
The packet memory diagnostic bootup test detected too many failures for switch
Refer to the Release Note attachment in the DDTS for CSCdz57255.
The packet memory diagnostic bootup test detected failures, but there are still a
Use the show diagnostic result module all detail command to see the test
The system detected free cell duplication, and will be reset. This message may also
This is an informational message only. No action is required.
Chapter 2
Messages and Recovery Procedures
buffers are available to continue booting.
OL-13091-01