CHASSIS Messages
Error Message C4K_CHASSIS-3-OUTOFMEMORY:Ran out of memory - cannot allocate internal
buffers
Explanation
Recommended Action
Error Message C4K_CHASSIS-3-POWERSUPPLYSEEPROMINVALID: Invalid data in power supply
[dec]'s serial eeprom
Explanation
Recommended Action
power supply.
Error Message C4K_CHASSIS-3-SEEPROMREADFAILEDAFTERWRITE:Error reading back module
[dec]s serial EEPROM data after write
Explanation
to read it back in, to ensure that the correct values were written out. What the switch read back in
differs from what the switch wrote out. The read or write might fail if the module is not seated
correctly in the slot.
Recommended Action
problem persists, contact your technical support representative. You will likely have to return the
module to Cisco to reprogram or replace the serial EEPROM.
Note
Error Message C4K_CHASSIS-3-TRANSCEIVERCRCINTEGRITYCHECKFAILED: transceiver
integrity check on port [char] failed: bad crc
Explanation
transceiver. Only Cisco-qualified transceivers are supported. Other transceivers will cause the
associated port to show as faulty.
Recommended Action
Error Message C4K_CHASSIS-3-TRANSCEIVERINTEGRITYCHECKFAILED: transceiver integrity
check on port [char] failed: bad key
Explanation
associated port to show as faulty.
Recommended Action
Catalyst 4500 Series Switch Cisco IOS System Message Guide
2-10
The switch ran out of memory in the temporary buffers.
If this message reappears, reboot the switch.
The power supply serial EEPROM could not be read or has not been programmed.
Try re-inserting the power supply. If that doesn't work, replace it with a new
After writing a module's serial EEPROM in response to a CLI request, the switch tried
Remove and reinsert the module. If that does not work, reboot the switch. If the
Writing the module's serial EEPROM is not standard practice; when the module comes from
the factory, its serial EEPROM is set to the correct values. We do not recommend that you
change the factory defaults, because this action could cause the module to malfunction.
The checksum of the transceiver SEEPROM is not valid, indicating a bad or non-Cisco
Replace the transceiver with a transceiver that Cisco supports.
Only Cisco-qualified transceivers are supported. Other transceivers will cause the
Replace the transceiver with an transceiver that Cisco supports.