Redundancy-1 - Cisco Catalyst 4500 Series System Message Manual

Cisco ios system message guide ios release 12.2(37)sg
Hide thumbs Also See for Catalyst 4500 Series:
Table of Contents

Advertisement

REDUNDANCY Messages
REDUNDANCY-2
Error Message C4K_REDUNDANCY-2-HANDSHAKE_TIMEOUT_ACTIVE: The handshake messaging
between active and standby has not yet started.
Error Message C4K_REDUNDANCY-2-HANDSHAKE_TIMEOUT_STANDBY: The handshake messaging
between standby and active has not yet started.
Error Message C4K_REDUNDANCY-2-POSTFAIL_RESET:POST failure on ACTIVE supervisor
detected. [char]
Error Message C4K_REDUNDANCY-2-INCOMPATIBLE_SUPERVISORS: [char]
Error Message C4K_REDUNDANCY-2-IOS_VERSION_CHECK_FAIL: [char]
Catalyst 4500 Series Switch Cisco IOS System Message Guide
2-88
The initial handshake message exchange between active and standby supervisor engines
Explanation
has not yet started. Traffic on the active supervisor engine is not affected, but supervisor engine
redundancy will not work.
Please schedule a downtime ASAP and reset the active supervisor engine.
Recommended Action
The initial handshake message exchange between standby and active supervisor engines
Explanation
has not yet started. If the active supervisor engine has not completed its initialization, this message
may be seen temporarily on the standby supervisor engine. This condition will correct itself once
the active supervisor engine initialization is complete. If problems persist after the active supervisor
engine is initialized then redundancy will not work.
Please schedule a downtime ASAP and reset the active supervisor engine.
Recommended Action
The active supervisor engine failed POST but detected the standby supervisor engine at
Explanation
bootup. It is attempting to reset itself so that the standby supervisor engine can take over as the new
active supervisor engine.
You may need to replace the supervisor engine that failed POST. Contact your
Recommended Action
technical support representative.
For proper operation of redundancy, the supervisor engines must be of the same model.
Explanation
In this condition redundancy operations are not available and the standby supervisor engine is
disabled because the supervisor engines present are of different models.
Configure the hardware so that the active and standby supervisor engines are
Recommended Action
of the same model.
The active and standby supervisor engine software is different. In this condition,
Explanation
redundancy operations are not guaranteed.
Configure the active and standby supervisor engines to use the same version of
Recommended Action
software.
Chapter 2
Messages and Recovery Procedures
OL-13091-01

Advertisement

Table of Contents
loading