Chapter 2
Messages and Recovery Procedures

SPANTREE_VLAN_SW Messages

This section contains the spanning tree fast convergence (SPANTREE_VLAN_SW) message.
Error Message SPANTREE_VLAN_SW-2-MAX_INSTANCE:Platform limit of [dec] STP instances
exceeded. No instance created for [char] (port [char]).

Supervisor Messages

This section contains the supervisor engine specific (
Error Message C4K_SUPERVISOR-0-SUPNOTSUPPORTEDINCHASSIS: The WS-X4013+TS supervisor
is not supported in chassis type [char]
Error Message C4K_SUPERVISOR-3-SUPOCTALPHYMDIOREADERR:Failed to perform read
operation on Octal Serdes at address [dec] for the register at address [dec]
Error Message C4K_SUPERVISOR-3-POWERSUPPLYSTATUSREADFAILED: Failed to read power
supply [dec]'s status register
OL-13091-01
The number of currently active VLAN spanning tree instances reached a
Explanation
platform-specific limit. No additional VLAN instances will be created until the number of instances
drops below that limit.
Reduce the number of currently active spanning tree instances by either
Recommended Action
disabling some of the instances or deleting the VLANs that are associated with them. You need to
manually enable those spanning trees that cannot be created due to limited instances.
The WS-X4013+TS is supported only in the Catalyst 4503 chassis. Either the
Explanation
WS-X4013+TS supervisor engine is in a chassis with more than 3 slots, which is a misconfiguration
and not supported, or the chassis' serial EEPROM is programmed incorrectly and contains the wrong
chassis type.
If this chassis has more than 3 slots, the WS-X4013+TS is not supported in it.
Recommended Action
If the chassis has 3 slots, and you see this message, collect the output of the show idprom chassis
command and call Cisco TAC. This chassis needs to be returned to Cisco.
Unable to read the Octal Serdes on the supervisor engine.
Explanation
If this continues to happen, please contact your technical support
Recommended Action
representative to replace the supervisor engine.
Reading the power supply status register failed.
Explanation
Try reinserting the power supply. If the problem persists, hot swap it with a new
Recommended Action
power supply.