Appendix A
Power Supply Specifications
Table A-39
LED
INPUT OK 1, INPUT OK 2,
and
INPUT OK 3
220VAC 1, 2, and 3
FAN OK
OUTPUT FAIL
OL-5781-08
8700 W AC-Input Power Supply LEDs
Meaning
Green—Source voltage is OK. (Input voltage is 85 VAC or greater.)
Off—Source AC voltage falls below 70 VAC, is not present, or the
power supply is turned off.
Green—High-line AC is present on the respective AC inputs. (Input
voltage is 170 VAC or higher.)
Off—Source AC voltage falls below 170 VAC (running at low-line
voltage), is not present, or the power supply is turned off.
Green—Power supply fan is operating properly.
Off—Power supply fan failure is detected.
Red—One or more of the power supply DC-output voltages is out
of the normal operating range:
For +3.3 VDC output: 2.7–3.0 VDC (min); 3.6–3.8 VDC (max)
For +12 VDC output: 10.5–11.5 VDC (min); 12.6–13.0 VDC
(max)
For +42 VDC output: 38.0–40.0 VDC (min); 45.0–52.0 VDC
(max)
Off—All DC-output voltages are within normal operating ranges.
For proper operation of the OUTPUT FAIL LED, systems with
Note
single power supplies must be configured with a minimum of
one fan tray and one supervisor engine. Systems with dual power
supplies must have a minimum configuration of one fan tray, one
supervisor engine, and one additional module. Failure to meet
these minimum configuration requirements can cause a false
power supply output fail signal.