Catalyst 6503-E Switch
Table 1-4
Catalyst 6503-E Switch Specifications (continued)
Item
Humidity (RH), ambient
(noncondensing)
nonoperating and storage
Altitude, operating
Shock and vibration
Acoustic noise
Physical characteristics
Dimensions (H x W x D)
Weight
Airflow
1. RU = rack units
Catalyst 6500 Series Switches Installation Guide
1-12
Specification
5% to 95%
Certified for operation: 0 to 6500 ft
Designed and tested for operation: –200 to 10000 ft (–60 to 3000 m)
This switch complies with Network Equipment Building Systems (NEBS)
(Zone 4 per GR-63-Core) in the following areas:
Earthquake environment and criteria
Office vibration and criteria
Transportation vibration and criteria
Shock
Operational—5 G 30 ms, half-sine (IEC 68-2-27)
Nonoperational—20 G, 7.5 ms, trapezoidal
Vibration
Operational—3 Hz to 500 Hz,
Power Spectral Density (PSD)—0.0005 G
5 dB/octave roll off at each end. 0.5 hours per axis (1.12 Grms).
64 to 76 dB. International Organization for Standardization (ISO) 7779:
Bystander position operating to an ambient temperature of 86°F (30°C).
7 x 17.37 x 21.75 in. (17.78 x 44.12 x 55.25 cm).
Chassis requires 4 RU
The Catalyst 6503-E switch chassis is designed to install in standard
19-inch equipment racks that meet ANSI/EIA 310-D, IEC 60297, and
ETS 300-119 standards.
Chassis only: 33 lb (15 kg).
Chassis fully configured with 1 supervisor engine, 2 modules,
2 AC-input PEMs, and 2 AC-input power supplies: 85.4 lb (38.7 kg).
WS-C6503-E-FAN—282 CFM
Note
To maintain proper air circulation through the Catalyst switch
chassis, we recommend that you maintain a minimum 6-inch (15 cm)
separation between a wall and the chassis air intake or a wall and the
chassis air exhaust. You should also allow a minimum separation of
12 inches (30.5 cm) between the hot air exhaust on one chassis and
the air intake on another chassis. Failure to maintain adequate air
space can cause the chassis to overheat and the system to fail. On
Catalyst chassis in which the airflow is from front to back, the
chassis may be placed side-by-side.
2
/Hz at 10 Hz and 200 Hz.
1
.
Chapter 1
Product Overview
OL-5781-08