Cisco CTS-500 Configuration Manual page 136

Configuration guide for the cisco telepresence system
Table of Contents

Advertisement

Peripheral Status Messages
Table A-3
Peripheral Status (continued)
Notification
CtpPeripheralStatusCode
ctpEtherPeripheralStatus—
Information about a single peripheral
attached through an ethernet port.
ctpEtherPeripheralStatusEntry
ctpEtherPeripheralIndex
ctpEtherPeripheralIfIndex
ctpEtherPeripheralAddrType
ctpEtherPeripheralAddr
ctpHDMIPeripheralStatus—
Information about a single peripheral
attached through the HDMI port.
ctpHDMIPeripheralStatusTable
ctpHDMIPeripheralStatusEntry
ctpHDMIPeripheralIndex
ctpHDMIPeripheralCableStatus
ctpHDMIPeripheralPowerStatus
Cisco Unified Communications Manager Configuration Guide for the Cisco TelePresence System
A-6
Appendix A
MIBs, RFCs, and SNMP Trap Messages for the Cisco TelePresence System
Return Values
commError
noError (0)—Expected peripheral device is functioning through the attached
port.
other (1)—None of the states listed.
cableError (2)—Expected peripheral device has a cabling issue.
powerError (3)—Expected peripheral device has a power issue.
mgmtSysConfigError (4)—Expected peripheral device has a communications
management system configuration issue.
systemError (5)—Cisco Telepresence system error.
deviceError (6)—Expected peripheral device is attached but is not fully
functional.
linkError (7)—Expected peripheral device has a port level link issue.
Example
CISCO-TELEPRESENCE-MIB::ctpEtherPeripheralIfIndex.1.1 = INTEGER: 7
CISCO-TELEPRESENCE-MIB::ctpEtherPeripheralAddrType.1.1 = INTEGER: ipv4(1)
CISCO-TELEPRESENCE-MIB::ctpEtherPeripheralAddr.1.1 = STRING:
"10.16.123.4"
CISCO-TELEPRESENCE-MIB::ctpEtherPeripheralStatus.1.1 = INTEGER:
noError(0)
Cable
plugged (1)—Peripheral cable is plugged.
loose (2)—Peripheral cable is loose.
unplugged (3)—Peripheral cable is unplugged.
unknown (4)—Cannot detect peripheral cable status.
internalError(5)—Internal error.
Power
on (1)—Peripheral power is on.
standby (2)—Peripheral power is in standby mode.
off (3)—Peripheral power is off.
unknown (4)—Cannot detect peripheral power status.
internalError (5)—Internal error.
Example
CISCO-TELEPRESENCE-MIB::ctpHDMIPeripheralCableStatus.3.1 = INTEGER:
plugged(1)
CISCO-TELEPRESENCE-MIB::ctpHDMIPeripheralPowerStatus.4.1 = INTEGER:
standby(2)
CISCO-TELEPRESENCE-MIB::ctpHDMIPeripheralPowerStatus.7.1 = INTEGER:
off(3)