Wiring Input/Output Devices Of Doors - Honeywell MPA2C3 Installation Manual

Access control unit
Hide thumbs Also See for MPA2C3:
Table of Contents

Advertisement

1. Connect all readers from MPA2C1 to MPA2C3 panel to the designated OSDP1
2. Click "RESET ALL" button to reset addresses of all the connected reader to
3. Disconnect all the readers and follow the steps in "6.x.2 Address assignment

Wiring Input/Output Devices of Doors

Door Monitoring and Locking Devices set up
The MPA2C3 Access Control Panel supports up to 4 doors. Each door supports:
Two Inputs for
Door Contact (DrCnt) - a sensor that monitors the state of the door (open or closed
state)
Request to Exit (REX) device – A switch or sensor that allows a person to unlock the
door without a valid identifier (eg a card) to exit from the protected area. A REX
device is not needed if and OUT Reader on that door is applied.
Output for
Door lock / door strike / magnetic lock - a locking device that is controlled by the
panels Door output
There are 4 Red RJ45 terminals and in parallel 2 removable push-in terminal
blocks, designed to wire the inputs and output . The information card on the panel
identifies these terminals as eg DOOR1, AUX2, DOOR 4 (RJ45 Terminals) or as eg
DOOR2 / AUX2 or DOOR1 / DOOR3 (Terminal Blocks).
Note: RJ45 Connectors allow standard structured cable (CAT 5E / CAT6/7) to be used to
wire a door. A door connection convertor (PN:MPA2S5) converts these wires in 2
input connections and 1 outputs connection.
MPA2C3 Installation Guide
and OSDP2 terminals.
address 0
procedure for OSDP readers "
71