CHAPTER
1 0
APPENDIX
This appendix calls out Underwriter's Laboratory product listing considerations for
product deployment. These statements refer to:
Model
MPA2C3
MPA2C3-4
MPA2MPSU
MPA4MPSU
MPA2ENCMU
These products were tested to CAN/ULC 60839-11-1:2022, ALARM AND ELEC-
TRONIC SECURITY SYSTEMS - PART 11-1: ELECTRONIC ACCESS CONTROL
SYSTEMS - SYSTEM AND COMPONENTS REQUIREMENTS (IEC60839-11-
1:2013, MOD), Edition 2, Issue Date 05/31/2022 and UL 294, STANDARD FOR
ACCESS CONTROL SYSTEM UNITS, Edition 7, Revision Date 10/08/2018 Stan-
dards.
Tested readers configurations include HID Signo 20(OSDP & Wiegand) manufactured by HID,
OmniProx OP30 (Wiegand), Omni Smart 20K (OSDP & Wiegand) and OmniProx OP10 (Wiegand),
all manufactured by Honeywell.
The UL testing operating temperature range is -10°C ~ +49°C under Variable Ambient Test. And
the UL testing relative humidity is 93% at 32°C under Humidity Test.
Output Voltage for ReaderA/Door1: 10.34 Vdc to 12Vdc.
The Optional features detailed in ULC 60839-11-1:2022 Second Edition May 31,
2022 were not verified by UL.
The total max load to the system of adding additional battery lo ad will be around 3.3A.
Note: These products have undergone ULC 60839-11-1 test with Grade I and Indoor use.
ACS4C3 Installation Guide
Description
2 door Access Control Panel
4 door Access Control Panel
2 door Access Control Panel Kit
4 door Access Control Panel Kit
Access Control assemblies, Metal enclosure with PSU