Max output current at Door1/AUX1 output when
OUT1, AUX1 jumper onboard "12V" is used
(wet contact)
Max output Voltage at Door2/AUX2 output
when OUT2, AUX2 jumper onboard "12V" is
used (wet contact)
Max output current at Door2/AUX2 output when
OUT2, AUX2 jumper onboard "12V" is used
(wet contact)
Relay contact min switching voltage and current
** Connect either RJ45 or push in terminal block; do not connect same Door output on both RJ45 and push in terminal
block.
Inputs
Supervised Input range
Digital input
Output Voltage Range at Input interface (12V) DrCnt Door 1-2, DrCnt
Max output current at input interfaces (12V)
RS485 BUS interfaces
Voltage range at RS485 busses
Max output current at RS485 bus I/O devices
Max output current at RS485 bus Downstream
146
OUT 1 @ RJ45 **,
AUX 1 @ RJ45 **
OUT 1 @ push in terminal
block**,
AUX 1 @ push in terminal
block**
OUT 2 @ RJ45 or
OUT 2 @ push in terminal
block**,
AUX 2 @ RJ45 or
AUX 2 @ push in terminal
block**
OUT 2 @ RJ45 **,
AUX 2 @ RJ45 **
OUT 2 @ push in terminal
block**,
AUX 2 @ push in terminal
block**
OUT 1-2, AUX1-2, Aux
Outputs 5-8
DrCnt Door 1-2, DrCnt
AUX1-2
Aux Inputs IN 9-16
Rex Door 1-2, Rex AUX1-2 Short circuit to GND default
AUX1-2
Rex Door 1-2, Rex AUX1-2
Aux Inputs IN 9-16
RS485 BUS I/O devices @
RJ45,
RS485 BUS I/O devices @
screw terminal block,
RS485 BUS Downstream @
RJ45
RS485 BUS I/O devices @
screw terminal block
RS485 BUS I/O devices @
RJ45
RS485 BUS Downstream @
RJ45
500mA per RJ45, limited to 750mA @
12VDC combined over both door output
contacts
750mA @ 12VDC combined over both
door output contacts
10VDC ~ 14VDC
500mA per RJ45, limited to 750mA @
12VDC combined over both door output
contacts
750mA @ 12VDC combined over both
door output contacts
1mA @ 5VDC
2k2Ohm +-10% default,
1k, 4k7, 10k Ohm selectable.(supervised
selectable)
(Unsupervised / digital selectable)
10VDC ~ 14VDC
500mA
10VDC ~ 14VDC
500mA in total for RS485 Modulbus
combined over RJ45 and screw terminal
block RJ45, limited to 500mA
500mA in total for RS485 Modulbus
combined over both RJ45