Cables

Use industry-standard cables that meet the following specifications:
Table 6-1 Reader Cables
Connected device
Readers
Alarm sensors,
door sensors, REX/
egress buttons
Door Locking
devices
Recommended cable distances for readers and peripheral devices.
As readers can be connected only via the RJ45 terminals, the intention is to use
CAT cable. Via the MPA2RJ - RJ45 to terminal block convertor - other types of cable
can be used as well. The most common and most economic available cable cur-
rently is CAT 5E. We recommend that CAT5E F/UTP cable is used.
Note: Use only CAT x cable with 100% copper wires. We do not recommend cable with CCA
(Copper Cladded Aluminum) wires or CCS (Copper Cladded Steel) wires as this
decreases the maximum cable length to readers and locks significantly.
Note: When using the red RJ45 terminal connectors for door peripherals (locking device,
door contact and REX button) it is likely that the same cable will be used. The tests
have been performed with a 200mA lock.
154
Connection to
Description
panel
8 wire shielded cable
(Wiegand) 4 wire twisted pair
RJ45 READER
shielded cable suitable for
terminal
RS485 (OSDP) CAT5E / CAT6 /
CAT7 S/FTP or F/UTP
Alarm Inputs
Push in Terminal
2 wire shielded cable
block
RJ45 DOOR
CAT5E / CAT6 / CAT7
Terminal
S/FTP or F/UTP
Relay / AUX
Outputs
2 wire shielded cable
Push in Terminal
block
RJ45 DOOR
CAT5E / CAT6 / CAT7 S/FTP or
Terminal
F/UTP
Cable Specifications
Wire
Maximum
diameter
distance
See
AWG 18-26
Recommendations
up to 1000 ft
AWG 22-24
(300m)
See
AWG 18-26
Recommendations
See
AWG 18-26
Recommendations
See
AWG 18-26
Recommendations
MPA2C3 Installation Guide