Wiegand Mode Panel Setting - Honeywell MPA2C3 Installation Manual

Access control unit
Hide thumbs Also See for MPA2C3:
Table of Contents

Advertisement

Wiegand mode panel setting

The MPA2C3 2-door system Wiegand mode can manage up to 4 readers to support
2 doors with IN and OUT readers per door.
Note: Any Wiegand reader is supported for either 2-door or 4-door configuration. There is no
need for Wiegand hold wire supported readers.
Note: For retrofitting Wiegand hold wire configurations from MPA2C1 and MPA2C1-4, the
reader can be reused in the original MPA2C1 or MPA2C1-4 configuration. The hold
wire control will not be used in the MPA2C3 and will be in a state, that the reader will
function as normal.
To set up the MPA2C3 in Wiegand mode per door DIP Switch
Table 3-3 settings and Jumper
MPA2C3
(2 Door)
Reader
Mode
Wiegand
(DEFAULT)
Once the reader terminals have been set to Wiegand mode correctly, the two LEDs
on the RJ45 connector will have the following function:
Right green LED : OFF
MPA2C3 Installation Guide
DIP Switch
SW1
SW2
Bit 1: OFF
Bit 1&2: OFF
(OSDP1)
(EOL
OSDP1)
Bit 10: OFF
Bit 3&4: OFF
(OSDP2)
(EOL
OSDP2)
RDR 1 (JP13/JP14) and RDR 2 (JP15/JP16) both jumpers must be set
synchronized
Left yellow LED
Idle: OFF
Card reading and transmitting to panel: flashing
Jumpers*
RDR 1
RDR 2
Enable 1-
2
(Wieg.A/
B)
Enable 1-2
(Wieg.A/B)
Reader
Reader mode
Function
READER
READER 1 IN
Door1 IN reader
Wieg.A / OSDP 1
READER 1 OUT
Door1 OUT reader
Wieg.B / OSDP
1
READER 2 IN
Door2 IN reader
Wieg.A / OSDP 2
READER 2 OUT
Door2 OUT reader
Wieg.B / OSDP
2
45

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mpa2c3-4