Honeywell MPA2C3 Installation Manual page 57

Access control unit
Hide thumbs Also See for MPA2C3:
Table of Contents

Advertisement

Warning: Before wiring the reader, see the below table on power limitations
The below table describes the power limitations for the RJ45 reader terminals.
Please note the difference between internal power source (12V from panel) and
reader external power supply, inserted in the push in terminal blocks (READER V
EXTERN, GND). The power limitations are for both combined RJ45 reader termi-
nals.
Power source
Voltage range
internal: 10-
14VDC
internal: 10-
14VDC
External: 14-
24VDC
DOOR1/AUX1/
DOOR3
(READER V
EXTERN, GND)
External: 14-
24VDC
DOOR2/AUX2/
DOOR4
(READER V
EXTERN, GND)
MPA2C3 Installation Guide
Power limitation
@ RJ45 Reader
terminals
2-Door
4-Door
READER1 IN
READER1
READER1 OUT
READER3
READER2 IN
READER2
READER2 OUT
READER4
READER1 IN
READER1
READER1 OUT
READER3
READER2 IN
READER2
READER2 OUT
READER4
Maximum current
RJ45 terminal
both RJ45 terminals
combined
500mA
500mA
500mA
500mA
500mA
500mA
500mA
1000mA
500mA
500mA
1000mA
500mA
51