Osdp Reader Address Assignment Feature Via Panel; Osdp Reader Controls - Honeywell MPA2C3 Installation Manual

Access control unit
Hide thumbs Also See for MPA2C3:
Table of Contents

Advertisement

Reader Connection

OSDP READER ADDRESS ASSIGNMENT FEATURE VIA PANEL

Usually OSDP readers are delivered with address "0".
The reader needs to be readdressed to the appropriate address for the assigned
function per the above table. The readdressing can be done with the addressing
tool of the reader (see instruction or installation manual of the reader manufac-
turer).
The MPA2C3 panel has an auto addressing function.The procedure is described
below.

OSDP reader controls

When an invalid card has been swiped to the reader, the access is denied to the
card holder and the reader red LED will flash twice and generates two beeps.
This is different than the Wiegand controls.
60
RJ45 Connector
mode
OSDP
READER
READER 1
Wieg.A / OSDP 1
READER 3
Wieg.A / OSDP 1
Reader Address
Reader Function
1
Door1 IN reader
2
Door1 OUT reader
3
Door3 IN reader
4
Door3 OUT reader