53 - Program Outputs
Option 53 – Program Outputs
This option is used by the engineer to modify the programming of the outputs on the system. The option also
allows the attributes of the outputs to be changed. The programmable options are:
Attributes
1
Output Function
2
Output Mode
3
Output Polarity
4
Diag. Recording
5
Output Groups
Note: Groups only appear if the Group option is enabled
(refer to option 63.1 = OPTIONS. Groups).

Selecting Outputs

On entering the option, the first output on the system is displayed; the output address, function and mode are
displayed on the top line, the polarity and assigned groups are displayed on the bottom line.
From the display of the first output, any output on the system can be displayed by pressing the A or B keys or
by entering the address of a specific output.
The output is selected for programming by pressing the ent key; the first output programming attribute 1=Op
Function is displayed.
Galaxy 3 Series Programming Manual
Description
Assign output type
1 = Latch - requires valid code to reset
2 = Reflex - follows activation status of zones
3 = Pulse (001 - 3000 secs) - activates for programmed period
0 = POS - 12V going to 0V in activation
1 = NEG - 0V going to 12V in activation
Assigns output to be active during Diagnostic Test
Assign groups to the output
Table 19. Output Attributes