52 - Program Zones (cont'd)
1 = Function
Entering the Function attribute displays the address and the current function of the selected zone along with
the zone function reference number. The zone functions can be stepped through, forwards or backwards,
using the A and B keys. Alternatively a zone function can be directly selected by entering the zone function
reference number, for example, entering the 19 displays zone function 19 = FIRE.
Once the required zone function is displayed, it is assigned to the zone by pressing the ent key.
2 = Descriptor
Each zone can be assigned with an alpha-numeric descriptor of up to 16 characters. This descriptor is assem-
bled from the character set and/or library options. On selecting the Descriptor attribute, the currently as-
signed descriptor (blank by default) is displayed on the top line - an underscore shows where the next charac-
ter will be positioned, and a selection of the alphabet is shown on the bottom line - the cursor flashes on the
letter L.
Press the
key to erase the characters already assigned to the descriptor.
The A or B keys can be used to move the alphabet left or right until the required character is positioned
underneath the flashing cursor. When the required character is in position press the ent key to copy the char-
acter to the descriptor in the top line. Repeat this procedure to assemble the required zone descriptor.
Text Case and Library
On entering the Descriptor attribute the alpha-numeric characters are all presented in upper case. Pressing
the # key toggles the characters to lower case.
Pressing the # key when the lower case alphanumeric characters are displayed toggles to the library words.
The words can be viewed using the A or B keys or directly selected using the reference number - refer to
Appendix A - Library. When the required word is displayed, press the ent key to copy it to the descriptor.
NOTE: Library words are a maximum of 12 characters and upper case only.
3 = Chime
If the Chime attribute is set to 1 (enabled) the zone will chime momentarily whenever it is opened while the
system is unset. The Chime attribute defaults to 0 (disabled) for all zone functions.
The A or B keys can be used to toggle the status of the Chime attribute — pressing 1 or 0 will also select the
required status; press the ent key to accept the programming.
NOTE: The Chime option (full menu option 15, quick menu option 2) must be enabled if the zones are to
chime when opened.
4 = Omit
If the Omit attribute is set to 1 (enabled) the zone can be omitted from the system by using one of the omit
functions (11 = OMIT ZONES, 14 = FORCED SET, 46 = GROUP OMIT). The Omit attribute defaults
to 0 (disabled) for all zone functions.