Honeywell Galaxy 3-48C Programming Manual page 62

Hide thumbs Also See for Galaxy 3-48C:
Table of Contents

Advertisement

51 - Parameters (cont'd)
Zones that are open at the end of the bell time must be omittable (Omit attribute enabled); the re-arm will omit
these zones. The complete zone circuit, including the tamper facility, is omitted. Refer to menu option 52 =
PROGRAM ZONES for details on enabling the zone omit attribute.
NOTE: If an open zone is not omittable, then the system will not re-arm, unless parameter 09 = Omit All is
set to 2.
09 = Omit All
This option determines if activated zones can be omitted at re-arm as described above.
0 = Disabled
1 = Omit All When set to 1 (enabled), omits any omittable zones that are open at re-arm. The complete zone
circuit including tamper is omitted.
2 = Force. As Omit All but omits zones whether omittable or not.
Refer to menu option 52 = PROGRAM ZONES for details on enabling the zone omit attribute.
10 = Key "0"
Key 0 on the keypad can be assigned to operate as a Push-set zone function; this will terminate the timed
setting procedure. When the option is set to 1 (enabled), pressing key 0 during the exit time completes the
setting of the system. The default is 0 (disabled).
NOTE: Key 0 must be pressed only on the keypad used to start the setting procedure.
11 = Local Part
When the Local Part parameter is set to 0 (disabled - default setting) the Intruder outputs are disabled when
the system is part set; the programmed bell delay is overridden. This is normally used to prevent the communi-
cator from dialling the Alarm Receiving Centre.
If the Local Part parameter is set to 1 (enabled) the Intruder outputs activate if an alarm condition occurs
when the system is part set.
Option 2 (SIA part off) is identical to option 1 with the exception that when the alarm format of the telecom
module is set to SIA then the part setting and unsetting of the system is not signalled to the ARC.
This parameter can be assigned a different value for each group.
12 = Banner
This option can be used to customise both the top and bottom lines of the banner display. Press 1 to select
the TOP LINE or 2 to select the BOTTOM LINE; the display is written using the alpha-numeric assembly
method:
erases characters;
selects upper case, lower case or library;
#
selects alphabet character/words;
A B
selects alphabet character or words;
000–500
positions selected characters/words;
ent
accepts the programming and returns to the previous level; exits from the option.
esc
The banner is displayed when the system is in the normal mode (set/unset).
Galaxy 3 Series Programming Manual
56

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Galaxy 3-144Galaxy 3-144cGalaxy 3-520Galaxy 3-520c

Table of Contents