Option 54 - Links; Programming Links - Honeywell Galaxy 3-48C Programming Manual

Hide thumbs Also See for Galaxy 3-48C:
Table of Contents

Advertisement

Galaxy 3 Series Programming Manual
Option 54 – Links
The Links option offers a powerful method of interconnecting zones, output functions, codes, keypads, and
MAX modules. The links table is constructed by creating a link between one of the source types and a valid
destination type. Activating the source of a link activates the destination – this can be used to switch outputs
on and off to omit zones, codes, keypads and MAX modules from the system.
The links function allows MAX/MicroMAX/MAX
destination is programmed as MAX/MicroMAX/MAX
MicroMAX/MAX
3
door relay will open for the duration the link is active. During this period no MAX alarms
are generated if the door contact timeout is exceeded. The on-board horns are deactivated and the green
open LED will be illuminated throughout.
When the link is deactivated the MAX/MicroMAX/MAX
the programmed relay duration period. - simulates an egress button activation.
If a max is disabled as the destination of a link, a card swiped at the max will still cancel an alarm or unset the
system. However it will not activate the relay or do a max function.
The number of links that can be assigned on each of the Galaxy systems is:
• Galaxy 48 = 64
• Galaxy 144 = 128
• Galaxy 520 = 256

Programming Links

On selecting the Links option, the details of Link 01 are displayed. If no link has been assigned the screen
displays 01 NOT USED.
The details of each link can be displayed using the A and B keys, or a specific link can be selected by entering
the required link number, for example 05, 29. When the required link is displayed, press, the ent key to begin
the programming procedure. The system prompts for the Link Source to be assigned. If groups are set then
some sources and destinations will not be available for programming:
1. Press the # key to select the required link source from the available types (refer to Table 23. Link
Source ).
2. Press the A or B keys to select the actual link source (for example, the zone address or the user code
number).
3. If the source is required to toggle the destination on and off, press the
on the display.
NOTES:
1. The link destination is activated by the first operation of the source and then deactivated by the second
operation.
4. Press the ent key; the source of the link is assigned and the keypad prompts for the link destination to be
allocated.
5. Press the # key to select the required link destination from the available types (refer to Table 24. Link
Destination).
6. Press the A or B keys to select the actual link destination (for example, the zone address or the output
type). To cancel a link program the source as not used.
7. Press the ent key.
destinations to be assigned a ( ) star function. If the
3
and the ( ) star is allocated, the assigned MAX/
3
3
horn sounds and the door relay remains open for
101
54 - Links
key. The source is prefixed by a

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Galaxy 3-144Galaxy 3-144cGalaxy 3-520Galaxy 3-520c

Table of Contents