Galaxy 3 Series Programming Manual
24 Batt Test
This output is activated when a battery load test is in progress. Refer to option
61.1.4 = Diagnostics.Latest.PSU Comms.
25 Wrong CD
This output is activated whenever a wrong code alarm occurs. That is, when six wrong codes in succession
are entered at the keypad. The output, by default pulses on for 90 seconds.
26 Alert (Latch)
The Alert output is activated when the control panel loses communication with one of the remote modules or
keypads.
27 Fire Delay (Latch)
The Fire Delay output is activated whenever a Fire zone is activated. The activation of the output is delayed
subject to the period determined by the 03=Abort Time parameter. The Fire Delay output is not subject to
the Rearm parameter: it latches on and remains active until a valid code (type 2 or above) is entered.
28 No Re-Arm (Latch)
The No Rearm output is activated on a full alarm event during the set state: it is subject to the Bell Delay
parameter. The No Rearm output is similar to the strobe output, but it stays on at the end of the bell time,
until unset.
29 Timer A (Reflex)
The Timer-A output is controlled by the Timer-A option (refer to option 65=Timers A/B) and activates in
accordance with the programmed on and off times assigned to the function.
30 Timer B (Reflex)
The Timer-B output is controlled by the Timer-B option (refer to option 65=Timers A/B) and activates in
accordance with the programmed on and off times assigned to the function.
NOTE: If the TIMER A or B outputs are programmed as LATCH mode, then they can only be reset by a
user code with access to all of the groups assigned to the relevant timer.
31 Walk Test (Reflex)
The Walk Test output is activated when a zone included in the walk test is tested (refer to option 31=Walk
Test).
32 Zone Omit (Reflex)
The Zone Omit ouput is activated as soon as a zone is omitted from the system by option 11=OMIT
ZONES or by option 54=LINKS. If the Output Mode attribute is assigned as:
Reflex (default) the output remains active until the zone is reinstated;
Latch the output is reset on entry of a valid code.
53 - Program Outputs (cont'd)