Honeywell Galaxy 3-48C Programming Manual page 208

Hide thumbs Also See for Galaxy 3-48C:
Table of Contents

Advertisement

Event Log (cont'd)
KEYPAD TEXT
RM ACCESS
Remote Access zone activated
+ SEC FINAL
Security Final zone activated (opened)
- SEC FINAL
Security Final zone closed (closed)
+ SECURITY
Security zone activated (opened).
– SECURITY
Security zone de-activated (closed).
SET LOG
Set Log zone activated (opened) when the system or group(s) is set.
SOAK TEST
Zone under Soak Test (Menu Option 55) activated when the system or group(s) is Set.
SPARE
Spare zone opened.
STANDLOW
Standby time for the battery is Low.
SUSP. SET
Setting of system suspended
SYS RESET
System Reset has occurred event.
+ TAMP C/V
constant Voltage tamper event
+ TAMP O/C
Zone changing to Tamper Open Circuit (greater than 12,000 Ohm).
– TAMP O/C
Zone changing from Tamper Open Circuit to Normal Closed (1200 to 900 Ohm).
TAMP RST
Tamper Reset of the system has occurred.
+ TAMP S/C
Zone changing to Tamper Short Circuit (less than 800 Ohm).
– TAMP S/C
Zone changing from Tamper Short Circuit (less than 800 Ohm). to Normal Closed (900 to 1200 Ohm).
Tamper on a module activated (opened). A module is either a keypad, Galaxy RIO, Telecom Module
+ TAMPER
or RS232 Module.
Tamper on a module de-activated (closed). A module is either a keypad, Galaxy RIO, Telecom
– TAMPER
Module or RS232 Module.
TEST O/P
Test Outputs menu (Menu Option 32) has been accessed.
TIMEOUT
Timeout alarm after the Entry Time has expired.
TIMER A +
Timer A activated (on).
TIMER A –
Timer A de-activated (off).
TIMER B +
Timer B activated (on).
TIMER B –
Timer B de-activated (off).
T/O-BURGL
Timeout alarm after the Entry Time has expired (same as TIMEOUT but used as a SIA event).
U/S EARLY
The Unset Early output has been activated before programmed time.
UNSET
Unset of the system or Group(s).
URGENT
Urgent zone activated.
VIBRATION
Vibration zone activated.
VIDEO
Video zone activated (opened).
VID EXIT
Video Exit zone activated (opened).
WALK TEST +
Walk Test has occurred.
WALK TEST –
Walk Test has finished.
WALL TAMP
Wall Tamper zone alarm.
WRONG CD
Wrong Code alarm activation (6 consecutive wrong codes). This Requires a system reset.
24 HOURS
24 Hours zone activated (opened).
NOTE:
M = Mandatory. NM = Non-Mandatory
NOTE:
A plus (+) means an event has started. A negative (-) means an event has finished.
Galaxy 3 Series Programming Manual
DESCRIPTION
D-6
Trigger Event
14. Menu Access
NM
4. Security
M
4. Security
M
18. Zone restoral
4. Security
M
4. Security
M
18. Zone restoral
16. Log zone
M
None
NM
16. Log zone
M
13. Elec status
M
None
NM
11. Reset/Cancel
NM
9. Tamper
M
9. Tamper
M
9. Tamper
M
18. Zone restoral
9. Tamper
NM
9. Tamper
M
9. Tamper
M
18. Zone restoral
9. Tamper
M
9. Tamper
M
18. Zone restoral
None
NM
10. Setting
M
None
NM
None
NM
None
NM
None
NM
2. Intruder
M
10. Setting
NM
10. Setting
M
3. 24 Hours
M
2. Intruder
NM
16. Log Zone
2. Intruder
M
2. Intruder
M
14. Menu access
NM
14. Menu access
NM
9. Tamper
M
9. Tamper
M
3. 24 Hours
M