Galaxy 3 Series Programming Manual
2 = MAX Address
The address and the on-line or standalone status of the MAX Modules are assigned and modified using this
option. On selecting MAX Address the Galaxy searches for the MAX with the highest address. The Galaxy
48 prompts for the AB line (1-1); the Galaxy 144 prompts for the AB line (1-2); the Galaxy 520 prompts for
the AB line (1-4) that is to be searched. Select the line and press the ent key. On locating the MAX, the
keypad prompts for the TYPE of MAX to be assigned:
0 = On-Line
The MAX is fully integrated with the Galaxy system and communicates via the AB line,
sharing system resources and facilities
1 = Standalone The MAX operates as an entirely independent unit. The Galaxy does not monitor the MAX
for alarms, tampers or power failure.
The MAX can then be readdressed. The keypad displays the current address of the MAX and the range of
valid addresses. All MAX modules default to address 7, it is recommended that when adding MAX modules,
the first is redressed as 0, the second as 1 and so on.
Enter the new MAX address and press the ent key; the Galaxy then reprograms the address of the MAX.
The keypad indicates the old and new MAX addresses and the status of the reprogramming.
When the reprogramming is complete the MAX bleeps and the display returns to 2 = MAX Address.
Old address
New address
3 = MAX Parameters
This option defines the individual operational features of each of the MAX/MicroMAX modules. On selecting
this option the address of the first MAX/MicroMAX on the system is displayed along with the descriptor
currently assigned to it. While the MAX/MicroMAX address is displayed on the keypad, the address pattern
on the MAX/MicroMAX module is indicated by the LEDs switching on. Pressing the # key displays a graphic
on the keypad which corresponds to the LED pattern on the MAX/MicroMAX module.
The following figure shows the graphic display for both a MAX and a MicroMAX address as 26.
The line numbers are represented by the top row in MAX and blocks 2
MicroMAX and the address numbers are represented by the bottom row of blocks in the MAX and the four
bottom blocks in the MicroMAX. The top LED on the MicroMAX is always off in this mode.
The combinations are shown in the following Figure:-
7 –> 0 [24]
7 –> 0 [24]
7 –> 0 [24]
7 –> 0 [24]
7 –> 0 [24]
MicroMAX LEDs Displayed
M A X
2 6
Top (unused)
Figure 11. LED Status
Line No.
1
2
3
4
Figure 12. Line Number/Module Address
63 - Options (cont'd)
Status of
reprogramming
MAX LEDs Displayed
M A X
2 6
Bottom
and 3
nd
Module Address
0
1
2
3
4
5
6
7