Galaxy 3 Series Programming Manual
1 = Schedule
This option controls the schedule for the initiation of communication for remote routine inspection. The sched-
ule can be set from 0-365 days. The default is 0 days which disables the function.
2 = Advice
This option controls the method by which communication is initiated. It can be initiated automatically by the
schedule programmed above or manually by user entry of the Service PIN code, with or without a notification
message. There are three options. The default value for each is disabled.
1 = Code Only
Entry of a Service PIN code automatically initiates a remote servicing connection to call back number 1.
The Service PIN code can only be modified by remote users. When the Service PIN code is entered,
it resets any scheduled connection timers.
2 = Code + Notice
This enables the remote servicing notification timer, and display of remote servicing notification. The
remote service notification message is not displayed if the system is set. It only becomes active when the
panel is unset. The message REMOTE CALL INIT, A=SP PIN ENTER is displayed on the keypad
after entry of a valid manager type user code.
3 = No Code/Notice
This enables a remote servicing session without the need for a Service PIN code and the panel's
remote servicing notification message. This option uses the start and end times programmed in menu
47.4.2.1 and 47.4.2.2 respectively.
7 = Service Pin
This is a 6-digit numeric Service PIN code (default 987654), which initiates an automated call to the Remote
Servicing application. The Service PIN code can only be changed from Galaxy Gold and sending the Service
PIN code to the panel via the Send Remote Access Start Code. The Service PIN code cannot be the same
as any other user codes on the system. This option is only available when option 47.4.6.1 (schedule) is greater
than 0 and when option 47.4.6.2.1 (code only) are enabled.
8 = Send Panel ID
When a remote servicing connection is established, this option allows panel identification and authentication.
When enabled, the following sequence of events occur.
Once a remote servicing connection is established, whether panel or PC initiated, the panel delays for a period
as determined by Delay Time for incoming information from the remote servicing package.
If a valid control character is received by the panel within the delay period, the panel transmits an identity
string. If no character is received during the delay period the call is terminated.
9 = Delay Time
This is the time that the panel delays for incoming information from the remote servicing package. The delay
time can be set from 3-10 seconds. The default is 3 seconds