Galaxy 3 Series Programming Manual
05 = Entry Time
This parameter determines the entry time allowed to users when unsetting the system. The Entry Time is
programmable within the range 0–300 seconds; the default is 45. Assigning a value of 000 seconds sets the
Entry Time to infinity.
This parameter can be assigned a different value for each group.
NOTE: A Final zone assigned a
Time for the group it is allocated to.
06 = System Reset
This option allows the engineer or the remote code to determine the type that can reset the system following
an intruder alarm. The default type is 3.6 — manager; the programmable range is:
• 2.3–2.5 for the user
• 3.6 for the manager
• 3.7 for the engineer
This parameter can be assigned a different value for each group.
NOTE: This option is affected by reduced resets, menu option 51.55.3.
The panel only requests Engineer Level Reset if alarms have been signalled, via the Communication Module
and appropriate type reset is set to 3.7. If no signal is transmitted, the reset will automatically reduce to type
3.6. This feature is only active when the DTMF signalling format is selected.
NOTE: This option can also be programmed from parameter 65 = Reset Levels.
07 = Tamper Reset
This option allows the engineer or the remote code to determine the code type that can reset the system
following a tamper. The default type is 3.7 — engineer; the programmable range is:
• 2.3–2.5 for the user
• 2.6 for the manager
• 3.7 for the engineer
This parameter can be assigned a different value for each group.
NOTE: This option is affected by reduced resets, menu option (51.55.3)
The panel only requests Engineer Level Reset if alarms have been signalled, via the Communication Module
and appropriate level reset is set to 7. If no signal is transmitted, the reset will automatically reduce to type
3.7. This feature is only active when the DTMF signalling format is selected.
08 = No. Re-Arms
The Number of Re-arms parameter determines the number of times that an armed system can re-arm the
bells, following an alarm activation. The default setting is 9 (infinite) with a programmable range of 0 – 9,
where 9 is infinite re-arm. If the option is enabled, then the system re-arms at the end of the programmed
confirm time - only if all zones are closed or are open and can be omitted, or if the Omit all force is enabled.
The intruder output remains active until a system re-arm occurs.
when programming the function will double the programmed Entry