3 = Any Set:
No access if any of the groups are set. The system must be fully unset, whether groups are enabled or not.
4 = Any Time (default):
Access available at any time
2 = Mode
1 = Direct
This permits access to be initiated from Galaxy Gold.
2 = Manager Authorize
If this option is selected here are two methods that an authorized user can use to enable access to the Galaxy
via Galaxy Gold:
Timed Access:
Galaxy Gold must access the Galaxy within 40 minutes of this option being enabled by the manager. Once
connected, there is no time limit on the access period. On terminating the connection, Galaxy Gold can re-
access the system within a 15 minute period of the termination.
Call Back:
The manager instructs the Galaxy to initiate a connection to a PC (with Galaxy Gold software loaded) by
dialling one of the numbers programmed in the Call Back option.
Refer to option 47 = Remote Access for details of how to initiate the Manager authorized connection.
3 = Call Back
Up to five telephone numbers can be programmed into this option. Galaxy Gold requests the Galaxy to call
back to one of the numbers.
NOTES:
1. If Manager Authorize is selected as the Remote Access Mode, then the ISDN module can only
make outgoing calls - it is disabled from answering all incoming calls.
2. If Call Back is selected, then access to the Galaxy is denied unless the call back option in Galaxy Gold
is used to initiate the connection.
10 Alarm Monitoring
This is identical to the Microtech format communications (56.1.3). This option is used to allow alarms to be
dialled to a PC with Alarm Monitoring software loaded as well as to an ARC using the Primary and/or Sec-
ondary formats.
11 Backup Module
This option allows another module to become the primary communication module if a line fail is detected on
the ISDN module. There are 6 options:
1 = Off; 2 = Ext Telecoms; 3 = Ext RS232; 4 = Ethernet; 5 = Int Telecom; 6 = Int RS232 1.