Galaxy 3 Series Programming Manual
47 = Set Confirm
This parameter allows the system to emit a short double beep when the system/group has set. There are three
options.
0 = Off
No indication
1 = Alert on Set
A double beep when the system has set
Alert on Comm
A double beep after a successful signal to the ARC that setting has occurred.
48 = Alarm Limits
This parameter allows the user to program the maximum number of alarms, per group, which may be transmit-
ted to an Alarm Receiving Centre in any set period. There are three options:
1 = No of Alarms
This is the total number of zone activations logged in any one set period. The selectable values are 0-10
where 0 is unlimited.
2 = Unset Limit
This is the number of activations logged from any one zone in any one unset period. The selectable values are
0-7. The default is 3. Fire and PA alarms are not restricted by this parameter.
3 = Set Limit
This is the number of activations logged from any one zone in any one set period. The selectable values are 0-
7. The default is 3.
Fire and PA alarms are not restricted by this parameter.
NOTE: This feature only affects Contact ID, SIA and Microtech communication formats.
51 - Parameters (cont'd)
65