Galaxy 3 Series Programming Manual
3 = Reduce Reset: This option allows user reset following an unconfirmed alarm.
0 = Off. Full system reset is required for any intruder alarm.
1 = On Unconfirmed. The system can be reset by user, if the alarm is unconfirmed. If the alarm is
classed as confirmed, a full system reset will be required.
56 = Force Restore
This option dictates when intruder restore signals are transmitted.
1 = Unset/Unconfirm: On unset or at the end of the confirmed time if the alarm is not confirmed.
2 = System Reset: Sent when the system is fully reset.
57 = Bell Extend
If enabled, this parameter extends the bell time if the system cannot rearm. For example , if the zone is still
open and cannot be omitted. The bell is extended by the number of modules programmed. Default is 0, no
extension.
58 = Power Alarm
If enabled, this parameter allows the Bells, Strobe and Horn outputs to activate when there is an AC fail and
the system is set. The default is 0.
59 = Part Tone
When enabled, this parameter changes the setting tone for a part set. The new tone is on 2 secs, off 0.1 sec.
60 = RF Parameters
1 = Supervision
This parameter has two sub options:
1 = Silent Alarm. If enabled, it stops Supervision alarms from activating sounders when set.
2 = Debounce. This extends the normal 2 hour delay for supervision by a further 24 hours.
61 = Activity Mon.
This parameter allows zone activity to be checked. If zones programmed for zone activity checks are not
activated within the programmed time period and/or number of set/unset cycles a zone masked fault is indi-
cated at the panel. Six different combinations of check criteria are available for each zone.
Each criteria type can be programmed to check the number of days, the set/unset cycles or both. Default
value is both.
1 = Mode
The mode can be set to one of three options: Max Period, Max Unsets or Either.
2 = MAX Period
The time period that zone activity is checked can be set to between 1 and 28 days. Default is 14 days.
3 = MAX Unsets
This is the number of programmable set/unset cycles that must take place before a zone masked fault is indi-
cated at the panel. The number of set/unsets can be programmed from 1 - 10. The default is 7.
51 - Parameters (cont'd)