Galaxy 3 Series Programming Manual
22 = PA Reset
This option allows the engineer or the remote code to determine the code type that can reset the system
following a PA activation. The default type is 3.6 — manager; the programmable range is:
• 2.3 - 2.5 for the user
• 3.6 for the manager
• 3.7 for the engineer
This parameter can be assigned a different value for each group.
The panel only requests Engineer Level Reset if alarms have been signalled, via the Communication Module
and appropriate type reset is set to 3.7. If no signal is transmitted, the reset will automatically be reduced to
type 3.6. This feature is only active when the DTMF signalling format is selected.
23 = Print Codes
The Print Codes option, when set to 1 (enabled), allows the manager to print a list of the PINS for each of
the users. The option defaults to 0 (disabled).
24 = Exit Alarm
If the Exit Alarm parameter is set to 1 (enabled), any zone other than Final, Exit, Entry or Push-Set (or
Secure Final or Part Final when acting as a Final) that is opened during the exit time causes a full alarm
condition to be activated. The default is 0 (disabled).
NOTE: This option must be used only when specified.
This parameter can be assigned a different value for each group.
If the Exit Alarm parameter is enabled, any zone that is open when the Autoset begins (at the end of the pre-
warning period) causes an immediate full alarm condition to be activated.
If the Exit Alarm parameter is disabled, any zone open when the Autoset begins (at the end of the pre-
warning period) results in an "urgent" bleeping from the Entry/Exit Horns. If the open zones are not closed
by the end the time assigned in parameter 35 = Fail To Set, a full alarm is activated along with any outputs
programmed as Fail-Set.
25 = Global Copy
The Global Copy parameter changes all zones within the selected range to the function of the first zone in the
range. On selection of the parameter, a warning message is displayed indicating that the zone functions will be
altered — WARNING!!! ENT=ZONE CHANGES: press the ent key to continue or the esc key to abort
the programming. The address and function of the first zone on the system are displayed:
Copy Start: Use the A or B key to select the first zone in the range to be copied and press the ent key.
The function of this zone will be copied to all subsequent zones in the range;
Copy End: Use the A key to move to the last zone in the range to be copied.
Press the ent key to copy the zone function to the selected range.
51 - Parameters (cont'd)