2.
Procedure (TASK 33-30-15-550-801-A01)
A.
Job Setup (Subtask 33-30-15-550-001-A01)
WARNING:
BEFORE YOU USE A MATERIAL, REFER TO THE MANUFACTURERS' MATERIAL
SAFETY DATA SHEETS. SOME MATERIALS CAN BE DANGEROUS.
CAUTION:
DO NOT USE MATERIALS THAT ARE NOT EQUIVALENT TO HONEYWELL
SPECIFIED MATERIALS. MATERIALS THAT ARE NOT EQUIVALENT CAN
CAUSE DAMAGE TO THE EQUIPMENT AND CAN MAKE THE WARRANTY NOT
APPLICABLE.
CAUTION:
DO NOT DROP OR HIT THE DOOR MOUNTED CARGO LOADING LIGHT DURING
THESE PROCEDURES. THE DOOR MOUNTED CARGO LOADING LIGHT
CONTAINS AN ASSEMBLY THAT CAN BE DAMAGED FROM INCORRECT USE.
CAUTION:
DO THESE PROCEDURES IN A CLEAN ENVIRONMENT TO PREVENT DAMAGE
TO MECHANICAL COMPONENTS.
(1)
Obey the precautions.
(2)
Refer to ATA No. 20-00-04 (Pub. No. A09-1100-001), Handling, Storage, and Shipping
Procedures for Honeywell Avionics Equipment Instruction Manual, for full instructions about
storage and transportation of the door mounted cargo loading light.
B.
Preservation (Subtask 33-30-15-550-002-A01)
(1)
Clean the door mounted cargo loading light with a A-A-59323 cleaning cloth to remove dirt,
dust, and unwanted material.
(2)
Do the preservation procedure for the door mounted cargo loading light. Refer to
MIL-STD-2073-1C, Method 41.
(3)
Put the door mounted cargo loading light in wrapping material, then in a plastic bag.
C.
Packing (Subtask 33-30-15-550-003-A01)
(1)
Put A-A-59135 dunnage, A-A-59136 cushioning, desiccant, and the door mounted cargo
loading light in a ASTM-D5118 shipping box, then seal with ASTM-D1974 tape.
D.
Storage (Subtask 33-30-15-550-004-A01)
(1)
Identify the ASTM-D5118 shipping box container. Refer to MIL-STD-129. Also, include the
overhaul date and location.
(2)
If the door mounted cargo loading light must be in storage for a long time, keep it in a location
with a temperature range of -22 to +131 F (-30 to +55 C).
E.
Transportation (Subtask 33-30-15-550-005-A01)
(1)
When equipment is sent to Honeywell for warranty repair, use the approved ATA container,
or equivalent.
F.
Job Close-up (Subtask 33-30-15-550-006-A01)
(1)
Remove all tools, equipment, and unwanted materials from the work area.
EFFECTIVITY
ALL
© Honeywell International Inc. Do not copy without express permission of Honeywell.
COMPONENT MAINTENANCE MANUAL
15-0705
33-30-15
Page 15002