Honeywell S283W703-6 Component Maintenance Manual With Illustrated Parts List page 49

Advertisement

Fault
Lamp (5, IPL Figure 1) does not
come on or not at full intensity.
NOTE:
F.
Job Close-up (Subtask 33-30-15-810-006-A01)
(1)
Remove all tools, equipment, and unwanted materials from the work area.
EFFECTIVITY
ALL
© Honeywell International Inc. Do not copy without express permission of Honeywell.
COMPONENT MAINTENANCE MANUAL
15-0705
Table 1003. Fault Isolation
Probable Cause
1. Defective lamp (5).
2. Electrical contacts (90),
terminals (100 and 110), or
lampholder (105) corroded or
damaged.
3. Electrical wires damaged or
broken.
The continuity check is a measure of resistance. If the measured resistance is
megohms, there is a break in continuity (equipment is faulty). Replace as necessary.
Corrective Action
1. Use a Fluke 8010A digital
multimeter to check lamp (5)
filament for continuity.
2. Remove and clean or replace
parts.
3. Use a Fluke 8010A digital
multimeter to check continuity.
If no continuity, replace broken
wires.
33-30-15
Page 1003
30 Mar 2017