Figure 7001. (Sheet 1 of 1) Lampholder Installation (GRAPHIC 33-30-15-99B-808-A01)
(7)
Align tabs of the lamp (5) with slots in the lampholder (105), then carefully push down on the
lamp (5) and turn clockwise 1/4 turn to attach.
(8)
Position the lens assembly (-20) on the light subassembly (-75) and tighten two captive
screws (65) to attach.
NOTE:
(9)
Test the cargo light. Refer to TESTING AND FAULT ISOLATION (PGBLK 33-30-15-1000), for
details.
(10) Install VARGLAS-H-C-2 tubing (TU420) and MIL-T-43435, Type II, Finish E lacing tape on
electrical wires. Refer to REPAIR (PGBLK 33-30-15-6000), for details.
(11) Slide the nipple (95) along electrical wires and over end of the lampholder (105) to cover the
electrical wire connections.
NOTE:
(12) (Post SB 15-0705-33-1) Identify on the cargo light identification plate (10, IPL Figure 1)
that MOD 1 is installed.
C.
Job Close-up (Subtask 33-30-15-400-003-A01)
(1)
Remove all tools, equipment, and unwanted materials from the work area.
EFFECTIVITY
ALL
© Honeywell International Inc. Do not copy without express permission of Honeywell.
COMPONENT MAINTENANCE MANUAL
15-0705
If the door mounted cargo loading light is being prepared for shipping, install nut
(-19).
(Post SB 15-0705-33-1) Do not put the cable nipple back on the cargo light.
33-30-15
Page 7003