2.
Procedure (TASK 33-30-15-100-801-A01)
A.
Job Setup (Subtask 33-30-15-100-001-A01)
WARNING:
BEFORE YOU USE A MATERIAL, REFER TO THE MANUFACTURERS' MATERIAL
SAFETY DATA SHEETS. SOME MATERIALS CAN BE DANGEROUS.
CAUTION:
DO NOT USE MATERIALS THAT ARE NOT EQUIVALENT TO HONEYWELL
SPECIFIED MATERIALS. MATERIALS THAT ARE NOT EQUIVALENT CAN
CAUSE DAMAGE TO THE EQUIPMENT AND CAN MAKE THE WARRANTY NOT
APPLICABLE.
CAUTION:
DO NOT DROP OR HIT THE DOOR MOUNTED CARGO LOADING LIGHT DURING
THESE PROCEDURES. THE DOOR MOUNTED CARGO LOADING LIGHT
CONTAINS AN ASSEMBLY THAT CAN BE DAMAGED FROM INCORRECT USE.
CAUTION:
DO THESE PROCEDURES IN A CLEAN ENVIRONMENT TO PREVENT DAMAGE
TO MECHANICAL COMPONENTS.
(1)
Obey the precautions.
(2)
Do the procedures in a clean location.
(3)
When you use pressurized air to clean assemblies and parts, do not use more air pressure
than is necessary.
(4)
After you clean the assemblies and parts, supply protection from moisture, dust, and other
contamination until you do a visual check and assemble the component.
(5)
Refer to ATA No. 20-00-03 (Pub. No. A09-1100-004), Standard Repair Procedures for
Honeywell Avionics Equipment Instruction Manual, for more cleaning procedures. Use the
standard repair procedures and approved local shop procedures.
B.
External Parts (Subtask 33-30-15-100-002-A01)
(1)
Remove dirt and dust with air supply with an air-ionizing gun attachment or air-ionizing nozzle
for compressed air lines or a soft-bristle brush.
(2)
Remove oil and grease that has collected on the door mounted cargo loading light. Use a
clean A-A-59323 cleaning cloth that is moist with Armakleen M-HP II aqueous cleaner.
(3)
To clean an area in a recess, use a stiff-bristle brush.
(4)
To remove unwanted material on painted surfaces that show index marks, numerals, or
letters, use a clean A-A-59323 cleaning cloth.
C.
Electrical Parts (Subtask 33-30-15-100-003-A01)
(1)
Remove dirt and dust around the connector pins with air supply with an air-ionizing gun
attachment or air-ionizing nozzle for compressed air lines.
(2)
Remove dirt and dust on the electrical parts with a soft-bristle brush or cotton swab that is
moist with Armakleen M-HP II aqueous cleaner.
(3)
Except for printed circuit boards, clean electrical parts with an A-A-59323 cleaning cloth dipped
in Armakleen M-HP II aqueous cleaner to remove dirt, dust, and unwanted material.
(4)
Clean printed circuit boards with a dry, A-A-59323 cleaning cloth to remove dirt or dust.
EFFECTIVITY
ALL
© Honeywell International Inc. Do not copy without express permission of Honeywell.