Electric Safety Lock - Honeywell ACS-8 Installation Instructions Manual

Table of Contents

Advertisement

Installation Instructions / ACS-8

16.5 Electric safety lock

The electric safety lock is available in a conventionally connectable variant (809) as well as in a BUS version (809N).
16.5.1
Electric safety lock conventional connection
The differential monitored inputs (inputs 5 - 10) must be terminated with 12KΩ resistor.
An additional third and/or fourth door can not be connected because input 6 is in use with
this connection.
Door monitoring
The interior door handle contact effects a door release through the ACS-8. The door can
be opened without the error message "Unauthorized door release".
An external contact, e.g. a magnetic contact, must be used for door monitoring. The state
of the bolt switching contact is only polled when the intrusion detection system is
"disarmed". Its status is therefore shown only when the intrusion detection system is
"disarmed". The bolt switching contact alarm group does not trigger or store an alarm when
the intrusion detection system is "armed".
97