Connecting A Door Strike; Connecting A Fail Secure Door Strike - Honeywell ACS-8 Installation Instructions Manual

Table of Contents

Advertisement

Installation Instructions / ACS-8

16.4 Connecting a door strike

16.4.1

Connecting a fail secure door strike

Fail secure door strike = strike with load current function: The door is released if the coil is energized
.
Tamper monitoring for the fail secure door strike is possible. For this, a DC door strike must be connected
as shown above.
This function is not possible with a fail save door strike and a door strike supplied with alternating voltage
or supplied by an external voltage source - not by the voltage source which supplies the ACS-8 -. The
tamper monitoring for "door strike 1" and "door strike 2" must be deactivated otherwise this causes a failure
on the ACS-8.
Terminal assignment ACS-8 :
With tamper monitoring
for relay 1:
for relay 2:
Without tamper monitoring (= standard)
for relay 1:
for relay 2:
For relay 3 and 4 there is no tamper monitoring possible.
jumper ST6 = 4 -6
jumper ST6 = 3 - 5
jumper ST6 = 2 -4
jumper ST6 = 1 - 3
95