Basic Standalone Operation

7.0 Basic Standalone Operation

7.1 Card Read / Door Lock Operation

1. Present a card to a reader.
2. The reader sends the card number to a reader input on the panel.
3. The panel searches its database and:

7.2 Door Egress (REX) / Door Lock / Door Status Operation

1. Activate the door egress input (REX).
2. The panel energizes the door relay associated with the particular
3. If the door status goes from close to open to close again during the
60
www.honeywell.com
• If it is a valid card, then energize the door relay associated with
the particular reader input. The card is valid when it is in the
card database on the panel and the current time and date
conforms to the time zone associated with the card.
• If it is not a valid card, the door relay remains locked.
door egress input for a default time of 10 seconds.
10 second door open period, the door relay will be immediately
de-energized.