Ent-Rmonth-<Mod2_Rmon; Table 2-11 Error Messages For Rtrv-Pm-<Mod2; Table 2-12 Error Messages For Ent-Rmonth-<Mod2_Rmon - Cisco ONS 15454 Reference Manual

Ons sonet tl1
Hide thumbs Also See for ONS 15454:
Table of Contents

Advertisement

2.10.2 ENT-RMONTH-<MOD2_RMON>
Table 2-11
Error Code
IDNV
IDNV
2.10.2 ENT-RMONTH-<MOD2_RMON>
The ENT-RMONTH-<MOD2_RMON> command creates a threshold type (an entry in the RMON alarm
table) for an RMON statistic, for the RMON-managed PMs. An event (TCA) is generated and reported
when the threshold is crossed in the appropriate direction during the sampled time period.
More than one threshold can be created by using different parameters (rising/falling threshold), for each
montype.
This command applies to G1000, GIGE, FSTE, POS, and FC data objects.
Input Format
ENT-RMONTH-<MOD2>:[<TID>]:<AID>:<CTAG>::<MONTYPE>,,,,<INTVL>:RISE=<RISE>,
FALL=<FALL>,[SAMPLE=<SAMPLE>,][STARTUP=<STARTUP >][:];
The following example creates an entry in the RMON threshold table for the etherStatsOctets statistic
Input Example
type with an interval equal to 100 seconds, rising threshold of 1000, falling threshold of 100, DELTA
sampling type and the startup type of RISING-OR-LTING.
ENT-RMONTH-GIGE:CISCO:FAC-2-1:123::ETHERSTATSOCTETS,,,,100:RISE=1000,
FALL=100,SAMPLE=DELTA,STARTUP=RISING-OR-LTING;
Table 2-12
Table 2-12
Error Code
IDNV
IDRG
IDNV
IIDT
IIDT
Cisco ONS SONET TL1 Command Guide, R6.0
2-62
Error Messages for RTRV-PM-<MOD2>
Description
TMPER Type Not
Supported
Current Interval Not
Supported For RMON PMs
shows the error messages associated with the ENT-RMONTH-<MOD2_RMON> command.
Error Messages for ENT-RMONTH-<MOD2_RMON>
Description
Invalid Interval
Invalid Threshold Value
Invalid MONTYPE value
Cannot Create More
RMON Threshold
Duplicate RMON
Threshold
Chapter 2
Scenario When the Error Message is Sent
The TMPER parameter specified is not applicable for
the MOD2 type. For example, 1-MIN is not applicable
for OC48 PM types.
The current interval is specified by default, or is
explicitly specified by mondat/montm, when the
TMPER is 1-MIN, 15-MIN, 1-HR, or 1-DAY.
Scenario When the Error Message is Sent
The input interval value is less than 10.
The rising/falling threshold is less than 0, or the falling
threshold is greater than or equal to rising threshold.
The montype is not applicable to the data type
(represented by the MOD2).
The number of RMON threshold created reached the
maximum (256).
There already is a threshold created with the exact
parameters.
Procedures and Provisioning

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15310-clOns 15600Ons 15327

Table of Contents